SmartConnect Touchscreen 1 Loop Addressable Fire Alarm SystemSimplicity Plus Analogue Addressable Fire Alarm System

Infinity ID2 Intelligent 2-Wire Fire Alarm System

MKII Soft & Hard Addressable Fire Alarm System

As a company who invests heavily in the development of our products we made a decision in 2011 to design a brand new addressable protocol which we have named the Fyreye MKII Protocol.

While the existing protocol has served Zeta Alarm Systems well for many years, it is a dated protocol, which has several limitations. The new Fyreye MKII Protocol has been designed to be flexible, with plenty of room for future expansion. This will allow us to continue developing innovative new products, without being restricted by protocol limitations imposed by the existing protocol.

A weak point of the existing protocol is error checking. We have taken the opportunity to increase the error checking capability eight fold. While this level of error protection could be considered overkill, we believe that the robustness this gives, will allow Fyreye MKII Protocol systems to function error free, even under extreme conditions.

Features Of Fyreye MKII Protocol

  • 250 devices per loop
  • 255 types of devices
  • Up to 3 analogue value readings
  • Read optical detector drift compensation value
  • Manufacturing date can be stored in each addressable device
  • Display battery level/signal strength of wireless devices
  • Improved sounder synchronisation
  • Quick start/stop loop powered sounders
  • Panels can trigger sounder with alert tone, alarm tone or emergency tone
  • Alarm tone selection from control panel (choice of 16 tones - 11 defined, 5 for future use)
  • Panel can read the device’s software version
  • 8 bit checksum for reliable communication
  • All devices can be softly addressed via a hand held programming tool
  • Approximately 50% of protocol commands are free for future expansion and development

MKII Soft & Hard Addressable Systems Brochure Download

MKII Soft & Hard Addressable Systems Brochure Download

Simplicity Plus Analogue Addressable Fire Alarm Panels

Simplicity Plus Analogue Addressable Fire Alarm Panels

The Simplicity Plus panels in metal enclosure has been designed to meet the latest additions to EN54 pt 4 with enhanced functionality including alarm verification, programmable zones, zonal & commown sounder operation and improved I/O unit options.

Model Number Description Loops Devices Download
SP-64/M Simplicity Plus 64 Analogue Addressable Fire Alarm Panel (Metal Enclosure)
CPD Number: 0359-CPD-0145
1 64 Datasheet
Brochure
EN54 Certificate
CertAlarm Certificate
CertAlarm Verification
Intertek Tick Mark Certificate
Installation Manual
User Manual
SP-126/M Simplicity Plus 126 Analogue Addressable Fire Alarm Panel (Metal Enclosure)
CPD Number: 0359-CPD-0145
1 126
SP-252/M Simplicity Plus 252 Analogue Addressable Fire Alarm Panel (Metal Enclosure)
CPD Number: 0359-CPD-0145
2 252
SP-REP Simplicity Plus Full Functional Repeater N/A Installation Manual

Flush Mounted Stainless Steel Simplicity Plus Analogue Addressable Fire Alarm Panels

Flush Mounted Stainless Steel Simplicity Plus Analogue Addressable Fire Alarm Panels

Model Number Description Download
Add /SS to the relevant model number Any of the above Simplicity panels in a Stainless Steel Flush Mount Enclosure  

Simplicity Accessories

Simplicity Accessories

Model Number Description
SP-FMB Flush Mount Bezel for Simplicity Panel, Quatro Repeater, 2A Power Pack

Simplicity Plus 252 with Panel Printer

Simplicity With Printer

Model Number Description Loops Devices Download
SP-252/P Simplicity Plus 252 With Panel Printer 2 252  

Simplicity Plus 252 Command Centre

Simplicity Command Centre

Model Number Description Loops Devices Download
SP-252/CC Simplicity Plus 252 Command Centre
Kindly refer to the Voice Evacuation & Telephone sections to view the range of components available
2 252  

Fyreye MKII Addressable LED Remote Indicators

Fyreye MkII Addressable LED Remote Indicators

A follow on from the ZTA-LE2, with detector alarm visual. Simply address the LED the same as the detector and the remote LED will do the rest. Also, through the handheld MKII programmer, up to 12 seperate addresses can be remotely indicated. The ceiling type modelfits on a MKII base.

Model Number Description Download
MKII-ARL/W MKII Addressable Remote LED Indicator (Wall Mounted) Datasheet
MKII-ARL/C MKII Addressable Remote LED Indicator (Ceiling Mounted) Datasheet

Fyreye MKII Sandwich Sounder/Flasher (LPCB Approved)

Fyreye MkII Sandwich Sounder/Flashers

The most flexible design, allowing sounder and/or sounder/flashers to be added to any MKII addressable detector in order to provide a local alarm. No change in wiring is needed and no need to address the sounder.

Model Number Description Download
MKII-SSB MKII Sandwich Sounder (No Address Required)
CPR Number: 0832-CPR-F0110
Datasheet
EN54 Certificate
CPR Certificate
MKII-SSFB MKII Sandwich Sounder/Flasher (No Address Required) Datasheet

Zeta TCP/IP Communicator

Zeta TCP/IP Communicator

Model Number Description Download
IP-COM Zeta TCP/IP Communicator in Enclosure Datasheet
User Manual
PCB/IP-COM PCB for Zeta TCP/IP Communicator Datasheet
User Manual

Further Information

Premier Quatro 4 Loop Spare Parts

Model Number Description
PCB/QT-DISP Quatro Display PCB (1-4 loops)
PCB/QT-TERM Quatro Termination PCB (1-4 loops)
PCB/PSUEN54/CTRL/5C Power Supply PCB (5A PSU card - CIE Version)
SPX-150-30 Power Supply cage (150W)

Premier Quatro 8 Loop Spare Parts

Model Number Description
PCB/QT8-DISP Quatro Display PCB (4-8 loops)
PCB/QT8-TERM Quatro Motherboard (4-8 loops)
DIN-300-29.5 Power Supply Module (300W)
PCB/QT-REP Quatro Repeater PCB

Simplicity Plus Spare Parts

Model Number Description
PCB/SP-64/D Simplicity Plus 64 Display PCB
PCB/SP-126/D Simplicity Plus 126 Display PCB
PCB/SP-252/D Simplicity Plus 252 Display PCB
PCB/SP-252/T Simplicity Plus Termination PCB
PCB/PSUEN54/CTRL/2C Power Supply PCB (2A PSU Card - CIE Version)
SPX-75-30 Power Supply Cage (75 W)
PCB/SP-REP/FF Simplicity Plus Full Function Repeater PCB

MKII Addressable Warning Devices

Sandwich Sounder

The Fyreye II Sandwich sounder base is a platform sounder that works with the Zeta Fyreye II protocol. The sounder can be triggered from it`s detectors remote LED output, allowing the sounders to be triggered individually. It can also be triggered using the Protocol`s common sounder group command, meaning that it can be triggered even if it`s detector has been removed.

Model Number Description Datasheets & Manuals
MKII-SSB MKII Sandwich Sounder (No Address Required)

Datasheet

Installation Manual

MKII-SSB/W MKII Sanwich Sounder - White (No Address Required) Datasheet

Xtratone Addressable Wall Sounder

The Xtratone sounders are small, high output addressable devices which are designed to meet EN54 part 3.

The device is a compact unit that fits a standard European back box and can be either surface or semi-flush mounted.

The Xtratone sounder has been designed so that field cables can be terminated in the back box as a first fix.

Model Number Description Datasheets & Manuals
MKII-AXT/R Xtratone Addressable Wall Sounder, Red

Datasheet

Installation Manual

MKII-AXT/W Xtratone Addressable Wall Sounder, White

Xtratone Addressable Combined Sounder Beacon

The new Xtratone addressable wall sounder with beacon has been designed to make an “electronics free” first fix and is available in red or white. The beacon has a coverage pattern of W 3.0 - 8.9 and the sounder part has 16 tones selectable at the control panel.

Model Number Description Datasheets & Manuals
MKII-AXTB/R Xtratone Addressable Combined Sounder Beacon, Red Body, Clear Flash

Datasheet

Installation Manual

MKII-AXTB/W Xtratone Addressable Combined Sounder Beacon, White Body, Clear Flash

Raptor Addressable Weatherproof Sounder

The Raptor addressable sounder is a large weatherproof horn sounder suitable for many indoor & outdoor applications.

It is available in red or white and has 16 tones selectable at the control panel. Termination of field wiring is made to the backbox for a clean first fix.

Model Number Description Datasheets & Manuals
ZRAP/R Raptor Addressable Weatherproof Sounder, Red

Datasheet

Installation Manual

ZRAP/W Raptor Addressable Weatherproof Sounder, White

Raptor Addressable Weatherproof Sounder Beacon

The Raptor addressable sounder with beacon has a coverage pattern of W 2.9 - 8.5 and the sounder part has 16 tones selectable at the control panel. It has a flash rates between 0.33Hz and 1.5Hz.

It has been designed to make an “electronics free” first fix and is available in red or white.

Model Number Description Datasheets & Manuals
ZRAPB/R Raptor Addressable Weatherproof Sounder Beacon, Red Plastic, White Flash

Datasheet

Installation Manual

ZRAPB/W Raptor Addressable Weatherproof Sounder Beacon, White Plastic, White Flash

 

MKII Addressable Interfaces

Fyreye MKII Addressable Input Module With Isolator

The ZAI-MI is used to monitor and raise alarm from any ancillary equipment such as sprinkler flow switch, aspiration detectors, secondary fire control panel, beam detectors, external power supplies etc.

Model Number Description Datasheets & Manuals
ZAI-MI Fyreye MKII Addressable Input Module with S/C Isolator (Loop Powered)

Datasheet

Installation Manual

Fyreye MKII Addressable Input/Output Module With Isolator

The ZAIO-MI is both an input and output module in a modern enclosure (2 gang box size) with well protected electronic circuit board to minimise any damages during installation.

Model Number Description Datasheets & Manuals
ZAIO-MI Fyreye MKII Addressable Input/Output Module with S/C Isolator (Loop Powered)

Datasheet

Installation Manual

Fyreye MKII Addressable Sounder Control Module With Isolator

The ZASC-MI can be used to supply a monitored 24Vdc to operate external relays and as a conventional sounder circuit to run bells or beacon flashers where the current consumption prohibits the use of addressable loop powered devices. The unit also includes input connections to monitor the external power supply status and report the findings to the addressable control panel.

Model Number Description Datasheets & Manuals
ZASC-MI Fyreye MKII Addressable Sounder Circuit Controller with S/C Isolator (Needs External Power Supply)

Datasheet

Installation Manual

Fyreye MKII Addressable Zone Monitor Module With Isolator

The ZAZM-MI is a conventional zone that can be used for conventional devices and/or for special detectors that are not available in addressable form such as UV detectors, Aspiration detectors etc.

Model Number Description Datasheets & Manuals
ZAZM-MI Fyreye MKII Addressable Zone Monitoring Unit with S/C Isolator (Loop Powered)

Datasheet

Installation Manual

Zeta Addressable Input/Output Module with Isolator - 230V Switching

Zeta Mains Switching IO

This interface can be used to switch 8A at 230V AC. It can only be addressed with it’s DIP switch

Model Number Description Datasheets & Manuals
ZAIO/230 Mains switching I/O unit - Fyreye MKII Protocol, 8A @ 230V AC

Datasheet 

Installation Manual

Special Mini Modules

Zeta MKII Special Mini Modules

Model Number Description Datasheets & Manuals
SMM/S Special Mini Modules (Yellow) - Alarm Devices
This module allows a conventional sounder or flasher to be connected to an addressable loop (Max current 12mA. 24 per loop).
 
SMM/B Special Mini Modules (White) - Beam Detector
This module allows the Zeta Beam - auto aligning beam detector to be connected to an addressable loop (Max 16 per loop).
 

Installation Manual

SMM/C Special Mini Modules (Red) - Call Point
This module provides a call point alarm input, that can be connected to a keyswitch to provide restricted alarm activation. It can also be used to connect to 3rd party conventional call points if required.
 

MKII Addressable Detector Bases

Bases For Standard MKII Addressable Detectors

The MkII range of detectors can be mounted on 3 different bases, a shallow base (MKII-CB), a deep base (MKII-CB/D) and an isolator base (MKII-IB).

Model Number Description Datasheets & Manuals
MKII-CB MKII Shallow Common Base

Datasheet

MKII-CB/D MKII Deep Common Base
MKII-IB MKII Isolator Base

New Zeta Addressable Base c/w Buzzer

Addressable Base c/w Buzzer for use with MKII-AOP, MKII-AHR, MKII-AHF & MKII-AOH.

Model Number Description Datasheets & Manuals
ZT-BUZ Addressable Base c/w Buzzer

Datasheet

Bases For MKII Addressable Detectors With Built-In Isolators

Fyreye MKII Addressable Common Base for use with MKII-AOPI, MKII-AHRI, MKII-AHFI & MKII-AOHI.

Model Number Description Datasheets & Manuals
MKII-CBI Fyreye MKII Addressable Common Base For Use With Detectors c/w Isolator

Datasheet

Detector Address Label Plate

Also available is a new Detector Address Plate (MKII-CB/DAP) which can be used with the MKII-CB and MKII-CB/D bases. An address label can be fitted to the plate allowing the detector’s address to be easily identified.

Model Number Description Datasheets & Manuals
MKII-CB/DAP MKII Addressable Label Plate

Datasheet

Black Detector Bases

The Fyreye MKII Addressable Detector bases are also available in black. To order add suffix "/B" eg. MKII-CB/B.

 

Assessed to ISO 9001:2015 - Certificate Number 330 DBI BSI Intertek VdS